Your future insurance and finance both rely on quality information being available at the time of purchase and resale.
Floor levels nz.
Review of survey practices in relation to the canterbury rebuild pdf 754 kb archive.
Branz level to within 5 mm within a single room or space.
Precision solutions specialises in foundation floor re levelling with extensive experience and an understanding of the christchurch canterbury landscape.
10 mm in total for lengths over 10 m.
Floor levels versus threshold levels.
There is no specific requirement in e2 as1 for a level change between the building finished floor level and the garage floor level.
Smartlift is proudly iso 9001 certified for commercial and residential foundation and floor levelling a grading that is recognised in more than 150 countries.
It acknowledges that floor levels could be the same as threshold levels.
Predicted water levels in the 1 in 50 and 200 year design events including climate change and sea level rise allowances.
B maximum length or width of floor of 24 0 m including any attached garage and c simple plan shapes such as rectangular l t or boomerang and d concrete slab on ground or suspended timber floor on piles and e maximum height of 2 0 m from finished floor level to adjacent cleared ground level and f simple roof forms incorporating.
Ph 0800 775 3835 email info precisionsolutions nz.
Don t accept substandard reports.
Floor levels getting the floor level wrong can lead to on going moisture problems.
Smartlift expertly levels and repairs foundations in commercial and residential buildings specialising in earthquake damaged properties in christchurch and canterbury.
Flat and straight to within 6 mm for every 3 m of length.
Figure 14 threshold levels relative to decks addresses threshold levels rather than floor levels as being critical for weathertightness.
All personnel on our work sites carry sitesafe passports.
Reference material for measuring floor levels following canterbury earthquakes.
Our reports focus on the key issues in the form of a summary.
It can also bring serious building code compliance problems and potential drainage problems due to an insufficient height of the floor above ground and lack of fall to the drains.
Flooring individual sheets or boards.
Interim floor level requirements for a residential dwellings.
Although figure 14 refers to decks the principal applies equally to general door thresholds.
Mbie 5 mm maximum deviation in any 10 m length.
Slope no more than 1 200.